GST40A Power Adapter

SPECIFICATION
ORDER NO. | GST40A05-P1J | GST40A07-P1J | GST40A09-P1J | GST40A12-P1J | GST40A15-P1J | GST40A18-P1J | GST40A24-P1J | GST40A48-P1J | |
OUTPUT |
SAFETY MODEL NO. | GST40A05 | GST40A07 | GST40A09 | GST40A12 | GST40A15 | GST40A18 | GST40A24 | GST40A48 |
DC VOLTAGE Note.2 | 5V | 7.5V | 9V | 12V | 15V | 18V | 24V | 48V | |
RATED CURRENT | 5A | 5.34A | 4.45A | 3.34A | 2.67A | 2.22A | 1.67A | 0.84A | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 5.34A | 0 ~ 4.45A | 0 ~ 3.34A | 0 ~ 2.67A | 0 ~ 2.22A | 0 ~ 1.67A | 0 ~ 0.84A | |
RATED POWER (max.) | 25W | 40W | 40W | 40W | 40W | 40W | 40W | 40W | |
RIPPLE & NOISE (max.) Note.3 | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±5.0% | ±5.0% | ±5.0% | ±3.0% | ±3.0% | ±3.0% | ±2.5% | ±2.5% | |
LINE REGULATION Note.5 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±3.0% | ±3.0% | ±3.0% | ±2.5% | ±2.5% | |
SETUP, RISE TIME Note.6 | 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 50ms / 230VAC 15ms / 115VAC at full load | ||||||||
INPUT |
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 84.5% | 87.5% | 88.5% | 89.5% | 90% | 90% | 91% | 92% | |
AC CURRENT (Typ.) | 1A / 115VAC 0.5A / 230VAC | ||||||||
INRUSH CURRENT (max.) | Cold start 35A / 115AC 65A / 230VAC | ||||||||
LEAKAGE CURRENT(max.) | 0.75mA / 240VAC | ||||||||
PROTECTION |
OVERLOAD | 105 ~ 150% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 5.2 ~ 6.8V | 7.8 ~ 10.2V | 9.4 ~ 12.2V | 12.6 ~ 16.2V | 15.7 ~ 20.3V | 18.9 ~ 24.3V | 25.2 ~ 32.4V | 50.4 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||
TEMP. COEFFICIENT | ±0.03% / ℃ (0~50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC (Note. 8) |
SAFETY STANDARDS Note. 7 | UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 , BIS IS13252,
KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved |
|||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||||
Conducted emission | EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32 |
Class B |
|||||||
Radiated emission |
EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32 |
Class B |
|||||||
Harmonic current | EN61000-3-2,GB9254 | Class A | |||||||
Voltage flicker | EN61000-3-3 | ——- | |||||||
EMC IMMUNITY |
Parameter | Standard | Test Level /Note | ||||||
ESD | EN61000-4-2 | Level 4, 15KV air; Level 4, 8KV contact | |||||||
RF field susceptibility | EN61000-4-3 | Level 2, 3V/m | |||||||
EFT bursts | EN61000-4-4 | Level 2, 1KV | |||||||
Surge susceptibility | EN61000-4-5 | Level 3, 1KV/Line-Line , 2KV/Line-FG | |||||||
Conducted susceptibility | EN61000-4-6 | Level 2, 3V | |||||||
Magnetic field immunity | EN61000-4-8 | Level 2, 3A/m | |||||||
Voltage dips , interruption | EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||||
OTHERS |
MTBF | 736.4K hrs min. MIL-HDBK-217F(25℃) | |||||||
DIMENSION | 125*50*31.5mm (L*W*H) | ||||||||
PACKING | 0.28Kg; 40pcs/12.02Kg/1.05CUFT | ||||||||
CONNECTOR | PLUG | See page 4~5 ; Other type available by customer requested | |||||||
CABLE | See page 4~5 ; Other type available by customer requested | ||||||||
NOTE | 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μf & 47μf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The demand for Malaysia safety is processed with the order no. GST40A -SIRIM by request. Please contact MEAN WELL for details. 8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on meanwellaustralia.au) |